Specifications BIA 101 Anniversary

  • Weight (device):  1.1 kg
  • Dimensions (device) in cm:  16 x 14 x 6.5
  • Measuring current:  0.3 mA, constant up to 5.000 Ohm
  • Measuring frequency: 50KHz sinusoidal
  • Power supply:  6 V battery, 1.2 Ah, rechargeable
  • Operation time: approx. 4 hours continuous
  • Resistance: 0…1000 Ohm
  • Reactance: 0…200 Ohm
  • Display:  back-lit LCD with direct readout of:  Rz / Ohm, Xc / Ohm, PA / Grad, C / Farad, BCM / kg, ECW / %,  UCR / mg/24h, BMR / KJ, RDNA-BFIndex / %
  • Interface: RS232
  • Safety norms:  CE Medical Device Class II A according to EU-Norm: 93/42/CEE – EN
  • 60601-1-2, EN46000, EN55011, ENV50140, IEC 1000-4-3 Device Type B
  • Included with BIA 101 Anniversary : Patient cable, charger, serial cable/USB adaptor, pack of electrodes, Bodygram® software, test unit, aluminum carrying case

BIA101 Anniversary is a product of Akern bioresearch srl, Pontassieve, Florence, Italy
www.akern.com

AKERN Phase Sensitive Bio-Impedance Analysis

AKERN BIA 101 Anniversary

The innovative Bio-Impedance Analyzer

  • Detailed analysis of body and tissue structure
  • Resistance, Reactance and Phase Angle, Capacitance
  • Direct measurement of cell mass with STA® modality without entry of personal data
  • Unique evaluation of nutritional state by » BIAGRAM® and » Biavector® according to Prof. A. Piccoli
  • Contemporary, simple user interface with smart dial
  • Direct indication of all results on built-in display
  • Totally portable use in ward and during visits

The portable bio-impedance analyzer BIA Anniversary is the latest development of Akern, together with its sister company RJL, the acclaimed leader in clinical BIA instruments, celebrating the 25th year of continuous production and world wide sales of the legendary » BIA 101 instrument. The implementation of latest electronics design and processor technology within the BIA 101 Anniversary guarantees precise measurement and reliable determination of body and tissue structure. The first time ever, body composition together with indicators for the one-glance graphical » Biavector® analysis are displayed in real time. Applying the proven STA® modality, directly measuring cell mass by capacitance, tests can be taken with or without co-predictors, such as age, gender, and weight. The built-in processor allows storage and management of test data (up to 80 complete tests). The novel smart dial enhances operation and speed of application. The BIA101 Anniversary is the right choice when an immediate reading of nutrition and hydration data is required e.g. in emergency, critical care medicine, on the ward or during visits. Data can be transferred to a PC by wireless transmission or printed on an optional handy thermo printer. On the PC data can be further analyzed, graphed, archived or printed with the BodyGram® PRO Software offering clinically validated algorithms and norms.

BIA101 Anniversary determines the following parameters:

  • Resistance (Rz) in Ohm
  • Reactance (Xc) in Ohm
  • Phase angle (PA) in degrees´
  • Bio-active cell mass (BCM) in kilograms and
  • Total body water (TBW) in liters and percent
  • Extra cellular water (ECW)in liters and percent
  • Intra cellular water (ICW) in liters and percent
  • Fat mass (FM) in Kilograms and percent
  • Fat free mass (FFM) in kilograms and percent
  • Ratio intra/extra cellular mass (ICM/ECM)
  • Muscle mass (MM) in kilograms and percent
  • Na/Ka exchange
  • Basic Metabolic Rate (BMR)  in kilocalories/kilojoules

…and the graphical one-glance evaluation by: